Smart Air Quality Monitor Indoor 12-in-1 CO2 Meter Dust PM1.0 PM2.5 PM10 Particles TVOC Detector HCHO Tester with Data Logger for Home AQI Test (128S)


$209.99

Smart Air Quality Monitor Indoor 12-in-1 CO2 Meter Dust PM1.0 PM2.5 PM10 Particles TVOC Detector HCHO Tester with Data Logger for Home AQI Test (128S)

Product Description

BLATN 128S Smart Air quality MonitorBLATN 128S Smart Air quality Monitor

PM2.5 PM1.0 PM10 TVOC HCHO CO2 Air quality monitorPM2.5 PM1.0 PM10 TVOC HCHO CO2 Air quality monitor

Fault description:

The machine suddenly shut down by itself, rebooting only lasts a second or two, or it can not turn on.

Solution: If the TF memory card is full, please replace it with a new card in time. Otherwise, there may be a sudden automatic shutdown of the machine, and can not open the machine.

If the above problems occur, try the following steps to rectify the fault:

1. Take out the TF memory card on the bottom of the machine

2. After power off, connect the charger to charge for more than 6 hours and then turn it on without the TF memory card to see if it can work.

6-channel Particle Number6-channel Particle Number

6-channel Particle Number

High precision laser particle sensor

User can view 6-channel particle count 0.3 0.5 1.0 2.5 5.0 10 and PM1.0 reading by switching the Curve Button (mode switch button)

PM0.3PM0.5PM1.0PM2.5PM5.0PM10

NDIR non-spectroscopic infrared CO2 sensorNDIR non-spectroscopic infrared CO2 sensor

NDIR CO2 optical measurementFull scale Temp. correctionAbsorption gas chamber optical coating72-hour Automatic baseline calibration

The percentage of constant constituents in the air is almost constant within 100km from the ground. In terms of volume content, oxygen accounts for approximately 20.95%, nitrogen accounts for approximately 78.09%, and CO2 is approximately 0.03%. The carbon dioxide concentration in the atmospheric environment is very stable, with a value of about 400ppm, even in a clean environment.

TF memory card data exportTF memory card data export

Data record and data export

TF memory card memory card that storage 100K+ data records

Data storage frequency: once a minuteConnect the computer via Card ReaderData records can be exported in TXT fileYou can use Excle to open TXT files to analyze data trends

 Air Quality Assessment AQI Air Quality Assessment AQI

Air Quality Assessment AQI Alarm

Air quality alarm threshold base on US standard:

PM2.5: 0-12μg/m³ GoodPM10: 0-54μg/m³ GoodCO2: 400-700ppm GoodTVOC: 0-5.0mg/m³ GoodHCHO: 0-0.1mg/m³ Good

3-way circular air convection3-way circular air convection

3-way circular air convection

Active air interaction systemincreases contact area with the sensormute fan with low noise

PE soft rubber shellPE soft rubber shell

Quality design

2.4-inch TFT liquid crystal displayEnergy absorption seismic designData curve trend

Add to Cart

Add to Cart

Customer Reviews

3.1 out of 5 stars 5

4.7 out of 5 stars 5

Price

$209.99$209.99 $179.99$179.99

PM1.0

PM2.5

PM10

TVOC

HCHO

CO2


no data

Particle Counter 0.3 0.5 1.0 2.5 5.0 10

Data record & Data Export

Precautions for Use

Regarding machine reading is high on first use Reason: Because the packaging material itself contains interference gas, and it is sealed in the box for a long time, the charge attached to the surface of the sensor will increase, causing the value of the machine to be biased when it is turned on. Solution: After receiving the machine, put it in an outdoor clean and ventilated environment for about 8 hours, so that the charge can be released. (Charger can be connected to ensure the power supply)

Regarding the high TVOC level Please check your measuring point if there are some human activities such as cooking, smoking, drinking or some chemical gases such as perfume, air freshener, detergent, etc. Then try to put the machine in an outdoor clean and ventilated environment for more than 3 hours to see if the machine value will drop.

About CO2 sensor calibration The CO2 sensor adopts 72-hour automatic baseline calibration. Plug in the charger, turn on the machine, click the test button, and let the machine run continuously for more than 72 hours.

About TVOC and HCHO calibration

We should calibrate the equipment in fresh outdoor air, because particulate pollution and chemical pollution are two different types of pollution. Very low particulate matter does not mean that chemical pollution and interfering gases do not exist.

To verify whether the machine sensor is normal, please pick up the machine to the mouth, blow hard into the air inlet of the machine, see if the value changes.

Test purifying effect of purifier: light a cigarette in a room, place our machine in this room, wait for the readings to go up, and then place the machine next to the hePA filter in another room to see if the high readings go down.

Put our machine directly next to the purifier and the reading might not change much. Because there is no change in the air concentration in a normal environment, and when you turn on the purifier, it is impossible to make the reading of air quality monitor become very low.

To ensure accurate readings, please test more than 20 minutes: After the machine is turned on, click the yellow test button and the machine will start reading. When the machine is just started to run, the value is constantly changing, because it takes a process for the value to rise from 0. After the machine runs for about 20 minutes and the reading tends to be stable.

When we test the air quality in a room, in order to ensure accurate results, we should keep the machine away from some interference factors, such as some perfume, incense, freshener, detergent and other interference gases, as well as smoking, cooking, drinking, human breathing and other human interference factors.

Product Dimensions ‏ : ‎ 2.72 x 1.69 x 5.63 inches; 8.16 ounces
Item model number ‏ : ‎ 128S
Batteries ‏ : ‎ 1 Lithium Polymer batteries required. (included)
Date First Available ‏ : ‎ January 30, 2024
Manufacturer ‏ : ‎ BLATN Tech
ASIN ‏ : ‎ B0CTPMQDFB
Country of Origin ‏ : ‎ China

【Laser Particle Sensor】The air quality detector adopts a high-precision laser fine dust sensor, which can detect air particles 0.3; 0.5; 1.0; 2.5; 5.0; 10 microns. It can real-time monitor the concentration of particulate matter PM1.0 PM2.5 PM10 in the air
【Real-time monitoring of indoor air quality】The air quality meter can continuously monitor the air quality in your home, office, or other indoor outdoor environments, can display the real-time data of CO2, PM2.5, PM1.0, PM10, TVOC, HCHO formaldehyde, carbon dioxide and 6-channel tiny particle number in the air
【Portable and Easy to Use】The home air quality testing kit has a small size and lightweight design, which is convenient to carry and use. It can be placed on a desk or carried in your pocket, making it suitable for home, office, and travel use
【Data logger】The air quality index AQI sensor has a built-in TF memory card which can store up to 10W+ pcs of data records. You can download the data to your computer through the card reader in TXT file and analyze it
【Multiple applications】The air quality analyzer is suitable for check the air pollution in your home and testing the chemical gas. It can be used to monitor air quality for allergies, asthma, and more. HAP hazardous airborn pollutant Standards Index AQI indicate

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Smart Air Quality Monitor Indoor 12-in-1 CO2 Meter Dust PM1.0 PM2.5 PM10 Particles TVOC Detector HCHO Tester with Data Logger for Home AQI Test (128S)”